Chamber capacity:ø25×D28CM (ø9.84×D11.02inch). Auto supply water system: Manual give the water. Safety valve: automatic discharge in excess of standard value. Uses the vapor power emissions cold air / 2 times.

Plug in the power cord. Shut exhaust needle valve in the Close (clockwise)°. Adding about 800 ml of distilled water.

Close the door cover, tight the rotate handle. Start the timer knob to 121. Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction). Wait for the pressure gauge pointer to zero, opened the door cover. Every time sterilization, must add about 800 ml of distilled water.

Use a separate socket (confirm the socket of the output voltage). Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valve.

Plate 3pcs (Size:20113621 mm). Take Plate tool 1pc steam exhaust pipe 1pc(1 meter length). Chamber capacity:ø25×D35CM (ø9.84×D13.78inch).

SAFETY : Heating-over protection ; safety valve. Pressure adjustment: adjust the inter pressure, if over standard value. Avoid overheat protect device: when inter temperature overheat, power break electric current automatically.

Temp and Press display :Led several windows. Before each use, distilled water is better. Do not use any corrosive or chemical water as the disinfection.

Do not share the same electricoutllet with other electrical apparetus. Please pay attention to correct voltage and frequency. Connect steam exhaust pipe with the steam vent. 18L Autoclave Steam Sterilizer Drying Function. Sterilize pressure: 0.12Mpa & 0.23Mpa.

Sterilize time: 25min & 6min. Tank Material: Stainless steel #304. Machine size (LWH): 60 39 36cm. Packing size (LWH): 61 53 40cm.

Application: For dental, surgery, beauty salon, medical care, laboratory, and so on. After the completion of disinfection, please to wait for 10 minutes. Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.

Before each use, must supply water 800ml of distilled water. Please close steam discharge valve before the disinfection.

The sale of this item may be subject to regulation by the U. Food and Drug Administration and state and local regulatory agencies.